Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
Nat Neurosci ; 26(11): 2005-2016, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37857774

RESUMO

The stimulation of deep brain structures has thus far only been possible with invasive methods. Transcranial electrical temporal interference stimulation (tTIS) is a novel, noninvasive technology that might overcome this limitation. The initial proof-of-concept was obtained through modeling, physics experiments and rodent models. Here we show successful noninvasive neuromodulation of the striatum via tTIS in humans using computational modeling, functional magnetic resonance imaging studies and behavioral evaluations. Theta-burst patterned striatal tTIS increased activity in the striatum and associated motor network. Furthermore, striatal tTIS enhanced motor performance, especially in healthy older participants as they have lower natural learning skills than younger subjects. These findings place tTIS as an exciting new method to target deep brain structures in humans noninvasively, thus enhancing our understanding of their functional role. Moreover, our results lay the groundwork for innovative, noninvasive treatment strategies for brain disorders in which deep striatal structures play key pathophysiological roles.


Assuntos
Destreza Motora , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Aprendizagem/fisiologia , Encéfalo , Corpo Estriado/fisiologia
3.
Nat Neurosci ; 26(11): 1994-2004, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37857775

RESUMO

Deep brain stimulation (DBS) via implanted electrodes is used worldwide to treat patients with severe neurological and psychiatric disorders. However, its invasiveness precludes widespread clinical use and deployment in research. Temporal interference (TI) is a strategy for non-invasive steerable DBS using multiple kHz-range electric fields with a difference frequency within the range of neural activity. Here we report the validation of the non-invasive DBS concept in humans. We used electric field modeling and measurements in a human cadaver to verify that the locus of the transcranial TI stimulation can be steerably focused in the hippocampus with minimal exposure to the overlying cortex. We then used functional magnetic resonance imaging and behavioral experiments to show that TI stimulation can focally modulate hippocampal activity and enhance the accuracy of episodic memories in healthy humans. Our results demonstrate targeted, non-invasive electrical stimulation of deep structures in the human brain.


Assuntos
Encéfalo , Estimulação Encefálica Profunda , Humanos , Encéfalo/fisiologia , Hipocampo/fisiologia , Estimulação Elétrica , Córtex Cerebral , Eletrodos Implantados , Estimulação Encefálica Profunda/métodos
4.
Bioelectron Med ; 9(1): 18, 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37553702

RESUMO

BACKGROUND: Peripheral nerve stimulation is used in both clinical and fundamental research for therapy and exploration. At present, non-invasive peripheral nerve stimulation still lacks the penetration depth to reach deep nerve targets and the stimulation focality to offer selectivity. It is therefore rarely employed as the primary selected nerve stimulation method. We have previously demonstrated that a new stimulation technique, temporal interference stimulation, can overcome depth and focality issues. METHODS: Here, we implement a novel form of temporal interference, bilateral temporal interference stimulation, for bilateral hypoglossal nerve stimulation in rodents and humans. Pairs of electrodes are placed alongside both hypoglossal nerves to stimulate them synchronously and thus decrease the stimulation amplitude required to activate hypoglossal-nerve-controlled tongue movement. RESULTS: Comparing bilateral temporal interference stimulation with unilateral temporal interference stimulation, we show that it can elicit the same behavioral and electrophysiological responses at a reduced stimulation amplitude. Traditional transcutaneous stimulation evokes no response with equivalent amplitudes of stimulation. CONCLUSIONS: During first-in-man studies, temporal interference stimulation was found to be well-tolerated, and to clinically reduce apnea-hypopnea events in a subgroup of female patients with obstructive sleep apnea. These results suggest a high clinical potential for the use of temporal interference in the treatment of obstructive sleep apnea and other diseases as a safe, effective, and patient-friendly approach. TRIAL REGISTRATION: The protocol was conducted with the agreement of the International Conference on Harmonisation Good Clinical Practice (ICH GCP), applicable United States Code of Federal Regulations (CFR) and followed the approved BRANY IRB File # 22-02-636-1279.

5.
Med Phys ; 50(3): 1779-1792, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36502488

RESUMO

BACKGROUND: Peripheral magnetic stimulation (PMS) is emerging as a complement to standard electrical stimulation (ES) of the peripheral nervous system (PNS). PMS may stimulate sensory and motor nerve fibers without the discomfort associated with the ES used for standard nerve conduction studies. The PMS coils are the same ones used in transcranial magnetic stimulation (TMS) and lack focality and selectiveness in the stimulation. PURPOSE: This study presents a novel coil for PMS, developed using Flexible technologies, and characterized by reduced dimensions for a precise and controlled targeting of peripheral nerves. METHODS: We performed hybrid electromagnetic (EM) and electrophysiological simulations to study the EM exposure induced by a novel miniaturized coil (or mcoil) in and around the radial nerve of the neuro-functionalized virtual human body model Yoon-Sun, and to estimate the current threshold to induce magnetic stimulation (MS) of the radial nerve. Eleven healthy subjects were studied with the mcoil, which consisted of two 15 mm diameter coils in a figure-of-eight configuration, each with a hundred turns of a 25 µm copper-clad four-layer foil. Sensory nerve action potentials (SNAPs) were measured in each subject using two electrodes and compared with those obtained from standard ES. The SNAPs conduction velocities were estimated as a performance metric. RESULTS: The induced electric field was estimated numerically to peak at a maximum intensity of 39 V/m underneath the mcoil fed by 70 A currents. In such conditions, the electrophysiological simulations suggested that the mcoil elicits SNAPs originating at 7 mm from the center of the mcoil. Furthermore, the numerically estimated latencies and waveforms agreed with those obtained during the PMS experiments on healthy subjects, confirming the ability of the mcoil to stimulate the radial nerve sensory fibers. CONCLUSION: Hybrid EM-electrophysiological simulations assisted the development of a miniaturized coil with a small diameter and a high number of turns using flexible electronics. The numerical dosimetric analysis predicted the threshold current amplitudes required for a suprathreshold peripheral nerve sensory stimulation, which was experimentally confirmed. The developed and now validated computational pipeline will be used to improve the performances (e.g., focality and minimal currents) of new generations of mcoil designs.


Assuntos
Magnetismo , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Estimulação Elétrica , Eletricidade , Estudos de Condução Nervosa
6.
Adv Healthc Mater ; 11(17): e2200075, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35751364

RESUMO

Electrical stimulation of peripheral nerves is a cornerstone of bioelectronic medicine. Effective ways to accomplish peripheral nerve stimulation (PNS) noninvasively without surgically implanted devices are enabling for fundamental research and clinical translation. Here, it is demonstrated how relatively high-frequency sine-wave carriers (3 kHz) emitted by two pairs of cutaneous electrodes can temporally interfere at deep peripheral nerve targets. The effective stimulation frequency is equal to the offset frequency (0.5 - 4 Hz) between the two carriers. This principle of temporal interference nerve stimulation (TINS) in vivo using the murine sciatic nerve model is validated. Effective actuation is delivered at significantly lower current amplitudes than standard transcutaneous electrical stimulation. Further, how flexible and conformable on-skin multielectrode arrays can facilitate precise alignment of TINS onto a nerve is demonstrated. This method is simple, relying on the repurposing of existing clinically-approved hardware. TINS opens the possibility of precise noninvasive stimulation with depth and efficiency previously impossible with transcutaneous techniques.


Assuntos
Estimulação Elétrica Nervosa Transcutânea , Animais , Estimulação Elétrica , Camundongos , Nervo Isquiático/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos
7.
Front Physiol ; 12: 693735, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34248680

RESUMO

The Data and Resource Center (DRC) of the NIH-funded SPARC program is developing databases, connectivity maps, and simulation tools for the mammalian autonomic nervous system. The experimental data and mathematical models supplied to the DRC by the SPARC consortium are curated, annotated and semantically linked via a single knowledgebase. A data portal has been developed that allows discovery of data and models both via semantic search and via an interface that includes Google Map-like 2D flatmaps for displaying connectivity, and 3D anatomical organ scaffolds that provide a common coordinate framework for cross-species comparisons. We discuss examples that illustrate the data pipeline, which includes data upload, curation, segmentation (for image data), registration against the flatmaps and scaffolds, and finally display via the web portal, including the link to freely available online computational facilities that will enable neuromodulation hypotheses to be investigated by the autonomic neuroscience community and device manufacturers.

8.
Nat Commun ; 12(1): 363, 2021 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-33441542

RESUMO

Aberrant neural oscillations hallmark numerous brain disorders. Here, we first report a method to track the phase of neural oscillations in real-time via endpoint-corrected Hilbert transform (ecHT) that mitigates the characteristic Gibbs distortion. We then used ecHT to show that the aberrant neural oscillation that hallmarks essential tremor (ET) syndrome, the most common adult movement disorder, can be transiently suppressed via transcranial electrical stimulation of the cerebellum phase-locked to the tremor. The tremor suppression is sustained shortly after the end of the stimulation and can be phenomenologically predicted. Finally, we use feature-based statistical-learning and neurophysiological-modelling to show that the suppression of ET is mechanistically attributed to a disruption of the temporal coherence of the aberrant oscillations in the olivocerebellar loop, thus establishing its causal role. The suppression of aberrant neural oscillation via phase-locked driven disruption of temporal coherence may in the future represent a powerful neuromodulatory strategy to treat brain disorders.


Assuntos
Encéfalo/fisiopatologia , Cerebelo/fisiopatologia , Estimulação Encefálica Profunda/métodos , Tremor Essencial/terapia , Estimulação Transcraniana por Corrente Contínua/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Tremor Essencial/diagnóstico , Tremor Essencial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Monitorização Neurofisiológica/métodos
9.
Commun Biol ; 4(1): 107, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33495588

RESUMO

Respiratory insufficiency is a leading cause of death due to drug overdose or neuromuscular disease. We hypothesized that a stimulation paradigm using temporal interference (TI) could restore breathing in such conditions. Following opioid overdose in rats, two high frequency (5000 Hz and 5001 Hz), low amplitude waveforms delivered via intramuscular wires in the neck immediately activated the diaphragm and restored ventilation in phase with waveform offset (1 Hz or 60 breaths/min). Following cervical spinal cord injury (SCI), TI stimulation via dorsally placed epidural electrodes uni- or bilaterally activated the diaphragm depending on current and electrode position. In silico modeling indicated that an interferential signal in the ventral spinal cord predicted the evoked response (left versus right diaphragm) and current-ratio-based steering. We conclude that TI stimulation can activate spinal motor neurons after SCI and prevent fatal apnea during drug overdose by restoring ventilation with minimally invasive electrodes.


Assuntos
Apneia/prevenção & controle , Diafragma/fisiologia , Terapia por Estimulação Elétrica/métodos , Overdose de Opiáceos/complicações , Traumatismos da Medula Espinal/complicações , Animais , Apneia/etiologia , Feminino , Masculino , Modelos Biológicos , Ratos Sprague-Dawley
10.
Commun Biol ; 3(1): 577, 2020 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-33067560

RESUMO

Neuromodulation is a new therapeutic pathway to treat inflammatory conditions by modulating the electrical signalling pattern of the autonomic connections to the spleen. However, targeting this sub-division of the nervous system presents specific challenges in translating nerve stimulation parameters. Firstly, autonomic nerves are typically embedded non-uniformly among visceral and connective tissues with complex interfacing requirements. Secondly, these nerves contain axons with populations of varying phenotypes leading to complexities for axon engagement and activation. Thirdly, clinical translational of methodologies attained using preclinical animal models are limited due to heterogeneity of the intra- and inter-species comparative anatomy and physiology. Here we demonstrate how this can be accomplished by the use of in silico modelling of target anatomy, and validation of these estimations through ex vivo human tissue electrophysiology studies. Neuroelectrical models are developed to address the challenges in translation of parameters, which provides strong input criteria for device design and dose selection prior to a first-in-human trial.


Assuntos
Estimulação Elétrica , Baço/inervação , Animais , Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/métodos , Fenômenos Eletrofisiológicos , Humanos , Baço/anatomia & histologia , Baço/irrigação sanguínea , Baço/citologia , Suínos
11.
Cell ; 169(6): 1029-1041.e16, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575667

RESUMO

We report a noninvasive strategy for electrically stimulating neurons at depth. By delivering to the brain multiple electric fields at frequencies too high to recruit neural firing, but which differ by a frequency within the dynamic range of neural firing, we can electrically stimulate neurons throughout a region where interference between the multiple fields results in a prominent electric field envelope modulated at the difference frequency. We validated this temporal interference (TI) concept via modeling and physics experiments, and verified that neurons in the living mouse brain could follow the electric field envelope. We demonstrate the utility of TI stimulation by stimulating neurons in the hippocampus of living mice without recruiting neurons of the overlying cortex. Finally, we show that by altering the currents delivered to a set of immobile electrodes, we can steerably evoke different motor patterns in living mice.


Assuntos
Estimulação Encefálica Profunda/métodos , Estimulação Transcraniana por Corrente Contínua/métodos , Animais , Estimulação Encefálica Profunda/efeitos adversos , Estimulação Encefálica Profunda/instrumentação , Eletrodos , Hipocampo/fisiologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neurônios/fisiologia , Estimulação Transcraniana por Corrente Contínua/efeitos adversos , Estimulação Transcraniana por Corrente Contínua/instrumentação
12.
PLoS One ; 11(9): e0161863, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27598923

RESUMO

INTRODUCTION: The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS: Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. RESULTS: Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. CONCLUSION: Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants.


Assuntos
Imageamento por Ressonância Magnética , Benchmarking , Campos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA